STREET LIGHTING SOLUTIONS

Street Lighting LED Driver Solutions

Programmable, surge-protected and intelligent constant-current LED drivers for urban roads, highways, residential streets, parking areas and smart city lighting systems.

High Efficiency Intelligent Dimming Surge Protection Long-Life Operation
Fahold F1 street lighting LED driver PROGRAMMABLE · IP67 · TIMER DIMMING
26W–320WRoad Lighting Platforms
90–480VacInput Voltage Options
Up to 10kVSurge Direction
DALI-2 / 0–10VSmart Control Options
ROAD LIGHTING ENGINEERING

Common Power Challenges in Street Lighting

Outdoor road-lighting drivers must survive electrical stress, operate efficiently for long nightly cycles and integrate with modern control systems.

Lightning & Surge Exposure

Long outdoor distribution lines increase exposure to induced lightning and switching surges.

Wide Input Voltage

Municipal and industrial projects may use 120V, 230V, 277V, 347V or 480V.

Long Nightly Operation

Drivers must remain stable through extended duty cycles and seasonal temperatures.

Energy & Dimming Control

Timer dimming and deep-night power reduction directly affect project energy use.

Smart City Compatibility

DALI-2, NFC, auxiliary power and node integration must match the control architecture.

Maintenance Complexity

Programmable current and switchable power reduce SKU quantity and simplify service.

APPLICATION MATCHING

Street Lighting Applications

Match each project to the correct input platform, control interface and mechanical installation method.

URBAN ROADS

Urban Roads & Main Streets

Programmable outdoor drivers for standard municipal street luminaires.

Recommended: F1
HIGHWAYS

Highways & Expressways

Higher-output road lighting with strong surge protection and remote dimming.

Recommended: F1
RESIDENTIAL

Residential Streets

Cost-controlled low- and medium-power neighborhood lighting.

Recommended: F1E / Z1
SMART CITY

Smart City Streetlights

Zhaga, DALI-2, NFC programming and intelligent-node integration.

Recommended: Z1
AREA LIGHTING

Parking & Area Lighting

Built-in drivers for shoebox fixtures and integrated luminaires.

Recommended: R1
HIGH VOLTAGE

347V / 480V Road Projects

Integrated luminaires for Canadian and industrial distribution systems.

Recommended: R1-T / R1-V
CORE PRODUCT PLATFORMS

Recommended Street Lighting Driver Series

Core families for global outdoor projects, intelligent streetlights and cost-optimized regional road lighting.

SMART CITY Z1 Series
Z1 Series

Zhaga Intelligent Driver

For connected streetlights using DALI-2, NFC and smart-city nodes.

  • Zhaga-oriented platform
  • DALI-2 / 0–10V
  • NFC / software programming
  • Smart-node compatibility
  • European public-lighting focus
Request Z1 Specifications
COST OPTIMIZED F1E Series
F1E Series

European Cost-Optimized Outdoor Driver

For residential roads and municipal replacement projects.

  • Regional input platform
  • Offline programming
  • 0–10V / PWM / timer dimming
  • IP-rated configurations
  • Retrofit project suitability
Request F1E Specifications
R1 Series

120–277V Built-In Platform

Shoebox, parking and integrated area luminaires.

R1-T Series

120–347V Integrated Platform

Canadian municipal and industrial projects.

R1-V Series

277–480V High-Voltage Platform

Industrial roads, ports and logistics parks.

QUICK PRODUCT MATCHING

Application-to-Product Matrix

Early-stage platform selection before detailed LED-array review.

Project TypeInput VoltagePower DirectionControlSeries
Global Standard Streetlight90–305Vac40–320W0–10V / TimerF1
European Residential Road180–265Vac40–200W0–10V / TimerF1E
Smart City Streetlight220–240Vac26–165WDALI-2 / NFCZ1
Shoebox / Parking Area120–277Vac100–320WProgrammable / DIPR1
347V Municipal Project120–347Vac100–320W0–10V / DIPR1-T
480V Industrial Road277–480Vac100–320WProgrammable / DIPR1-V
ENGINEERING PRE-SELECTION

Street Light Driver Engineering Calculator

Calculate driver sizing or estimate annual project energy using the actual dimmed input-power ratio.

Use the measured or specified input-power ratio. Do not assume that light-output percentage equals power percentage.
SMART CONTROL ARCHITECTURE

Street Lighting Power and Control Architecture

A complete system combines grid protection, programmable conversion, LED output and intelligent control.

AC Grid120–480Vac
Surge ProtectionProject-level SPD
FAHOLDLED DRIVER
LED DriverConstant current
LED ModuleMatched Vf and current
Street LuminaireRoadway distribution
Timer DimmingNight-time scheduling
0–10V / PWMExternal dimming
DALI-2 / Smart NodeConnected infrastructure
Auxiliary 12VController or sensor supply
APPLICATION ADVANTAGES

Why Fahold for Street Lighting

Outdoor power platforms engineered around reliability, inventory flexibility and modern controls.

Surge-Oriented Design

Platforms for electrically demanding outdoor distribution environments.

Programmable Output

Reduce driver SKUs across multiple fixture powers.

Timer Dimming

Reduce deep-night energy use without central control.

Smart City Integration

DALI-2, 0–10V and auxiliary power directions.

120–480V Platforms

Municipal, Canadian and industrial input options.

OEM / ODM Support

Current, cables, housing, labels and control functions.

OEM / ODM SUPPORT

Custom Road Lighting Power Solutions

Project-specific drivers around the LED voltage window, target current, input system, surge requirement, control method and mechanical installation.

Rated powerInput range Output voltage windowOutput current Dimming protocolTimer profile Auxiliary outputDIP switch Cable and connectorHousing dimensions IP ratingLabel and packaging
Discuss a Custom Project
FAHOLDSTREET LIGHTING DRIVERPower · Surge · Control · Integration
Timer ProfileNight-time stages
Smart ControlDALI-2 · 0–10V · NFC
Surge DirectionProject protection
Input Platform120V · 230V · 347V · 480V
RELIABILITY VALIDATION

Testing, Surge and Outdoor Reliability

Critical validation items for municipal, highway, parking and industrial projects.

Surge Testing

Confirm common- and differential-mode levels for driver and luminaire.

Weather Exposure

Review water ingress, condensation, cable entry and enclosure.

Long-Duration Operation

Validate output and temperature during nightly duty cycles.

Dimming Verification

Test timer steps, low-end stability and controller compatibility.

Burn-In & Protection

Review over-voltage, over-temperature and short-circuit behavior.

Market Compliance

Match certification scope to final luminaire and target region.

TECHNICAL FAQ

Frequently Asked Questions

Key questions for luminaire manufacturers, municipal buyers and project engineers.

How do I select an LED driver for a streetlight?

Match the constant-current operating window to LED minimum, nominal and maximum forward voltage, current, input voltage, power, surge, dimming, temperature and certification.

What surge rating is required?

The requirement depends on the distribution network, pole wiring, external SPD, luminaire insulation and local specification.

When should I choose DALI-2 or 0–10V?

DALI-2 suits addressable digital control. 0–10V suits simpler analog dimming. The interfaces must match.

What is timer dimming?

Timer dimming automatically changes output power during predefined night-time periods.

When is a 347V or 480V driver required?

Use these platforms when the facility distribution supplies 347V or 480V and the model is explicitly rated for it.

Can one programmable driver cover multiple powers?

Yes, when its adjustable current and operating window cover each LED configuration.

How is streetlight driver power calculated?

Nominal LED power is approximately nominal Vf × output current × channel count, with headroom and derating added.

What project information should I send?

Send input voltage, LED voltage range, current, fixture power, dimming, surge, environment, dimensions, wiring, quantity and market.

PROJECT INQUIRY

Get Your Street Lighting Solution

Send luminaire, LED-array, control, surge and market requirements. Calculator results transfer into the Elementor Pro form below.

Application-based recommendationInclude datasheets, drawings and surge specifications.
Open Inquiry Form
Scroll to Top